EASY512-DC-TC CONTROLADOR EASY PLC Marca Eaton-Moeller

$ 7,010.45 + IVA

  • USD: 347.65 $USD

Control relay, 24 V DC, 8DI(2AI), 4DO-Trans, display, time
Part no. EASY512-DC-TC
Catalog No. 274111
Entradas digitales: 8
Alimentación: 24 VCD
4 Salidas a Transitor
2 entradas Analógicas
Display: Si
Reloj tiempo real: Si

 

 

1 disponibles

Descripción

 572 total views,  1 views today

Delivery program
Product range
Control relays easyRelay
Basic function
easy500
Description
Stand alone
customized laser inscription or delivery with user program possible with EASY-COMBINATION-* product (article No. 2010781)
Inputs
Digital input count
digital: 8
digital: 8; of which can be used as analog: 2
Digital
8
of which can be used as analog
2
Outputs
Type
Transistor
Quantity of outputs
Transistor: 4
Outputs
Number 4
Transistor
4
Additional features
Display
with display, with keypad
Real time clock
Display & keypad
Supply voltage
24 V DC
Software
EASY-SOFT-BASIC/-PRO

Technical data
General
Standards
EN 55011, EN 55022, IEC/EN 61000-4, IEC 60068-2-6, IEC 60068-2-27
Dimensions (W x H x D)
mm 71.5 x 90 x 58 (4 PE)
Weight
kg 0.2
Mounting
Top-hat rail IEC/EN 60715, 35 mm or screw fixing using fixing brackets ZB4-101-GF1 (accessories)
Terminal capacities
Solid
mm2 0.2/4 (AWG 22 – 12)
Flexible with ferrule
mm2 0.2/2.5 (AWG 22 – 12)
Standard screwdriver
mm 3.5 x 0.8
Max. tightening torque
Nm 0.6
Climatic environmental conditions
Operating ambient temperature
°C In accordance with IEC 60068-2-1, -25 – +55
Condensation
Take appropriate measures to prevent condensation
LCD display (clearly legible)
°C 0 – 55
Storage
ϑ °C -40 – +70
relative humidity
% in accordance with IEC 60068-2-30, IEC 60068-2-78
5 – 95
Air pressure (operation)
hPa 795 – 1080
Ambient conditions, mechanical
Protection type (IEC/EN 60529, EN50178, VBG 4)
IP20
Vibrations
3,5 mm / 1 g Hz In accordance with IEC 60068-2-6
constant amplitude 0.15 mm: 10 – 57
constant acceleration 2 g: 57 – 150
Mechanical shock resistance (IEC/EN 60068-2-27) semi-sinusoidal 15 g/11 ms
Impacts 18
Drop to IEC/EN 60068-2-31
Drop height mm 50
Free fall, packaged (IEC/EN 60068-2-32)
m 1
Mounting position
Vertical or horizontal
Electromagnetic compatibility (EMC)
Overvoltage category/pollution degree
III/2
Electrostatic discharge (ESD)
applied standard
according to IEC EN 61000-4-2
Air discharge
kV 8
Contact discharge
kV 6
Electromagnetic fields (RFI) to IEC EN 61000-4-3
V/m 10
Radio interference suppression
EN 55011 Class B, EN 55022 Class B
Burst
kV according to IEC/EN 61000-4-4
Supply cables: 2
Signal cables: 2
power pulses (Surge)
according to IEC/EN 61000-4-5
1 kV (supply cables, symmetrical)
Immunity to line-conducted interference to (IEC/EN 61000-4-6)
V 10
Insulation resistance
Clearance in air and creepage distances
EN 50178, UL 508, CSA C22.2, No. 142
Insulation resistance
EN 50178
Back-up of real-time clock
Back-up of real-time clock
① Backup time (hours) with fully charged double layer capacitor
② Service life (years)
Accuracy of real-time clock to inputs
s/day typ. ± 2 (± 0.2 h⁄Year)
depending on ambient air temperature fluctuations of up to ± 5 s/day (± 0.5 h⁄year) are possible
Repetition accuracy of timing relays
Accuracy of timing relays (of values)
% ± 1
Resolution
Range “S”
ms 10
Range “M:S”
s 1
Range “H:M”
min 1
Retentive memory
Write cycles of the retentive memory
1000000 (10⁶)
Power supply
Rated operational voltage
Ue V 24 DC (-15/+20%)
Permissible range
Ue 20.4 – 28.8 V DC
Residual ripple
% ≦ 5
Siemens MPI, (optional)
yes (Notice: A short-circuit will result if 0 V or earth is applied to the outputs in the event that the supply voltage is connected to the wrong poles.)
Input current
normally 80 mA at Ue
Voltage dips
ms ≤ In accordance with IEC 61131-2
≤ 10
Fuse
A ≧ 1A (T)
Power loss
P W Normally 2
Digital inputs 24 V DC
Number
8
Inputs can be used as analog inputs
2 (I7,I8)
Status Display
LCD-Display
Potential isolation
from power supply: no
between digital inputs: no
from the outputs: yes
to interface/memory card: no
Rated operational voltage
Ue V DC 24
Input voltage
V DC Signal 0: ≦ 5 (I1 – I8)
Signal 1: ≧ 15 (I1 – I6), ≧ 8 (I7, I8)
Input current at signal 1
mA I1 – I6: 3.3 (at 24 V DC)
I7, I8: 2.2 (at 24 V DC)
Deceleration time
ms 20 (0 -> 1/1 -> 0, Debounce ON)
normally 0.25 (0 -> 1, Debounce OFF, I1 – I8)
Cable length
m 100 (unshielded)
Frequency counter
Number
2 (I3, I4)
Counter frequency
kHz ≦ 1
Pulse shape
Square
Pulse pause ratio
1:1
Cable length
m ≦ 20 (screened)
Rapid counter inputs
Number
2 (I1, I2)
Cable length
m ≦ 20 (screened)
Counter frequency
kHz < 1
Pulse shape
Square
Pulse pause ratio
1:1
Digital inputs 24 V DC
Status Display
LCD-Display
Analog inputs
Number
2 (I7, I8)
Potential isolation
from power supply: no
between digital inputs: no
from the outputs: yes
to interface/memory card: no
Input type
DC voltage
Signal range
0-10 V DC
Resolution
0.01 V analog
0.01 V digital
10 Bit (value 0 – 1023)
Input impedance
11.2
Accuracy of actual value
Two EASY devices
% ± 3
Within a single device
% ± 2, (I7, I8, I11, I12) ± 0.12 V
Conversion time, analog/digital
ms Input delay ON: 20; Input delay OFF: each cycle time
Input current
mA < 1
Cable length
m ≦ 30, screened
Transistor outputs
Number
4
Rated operational voltage
Ue V DC 24
Permissible range
Ue 20.4 – 28.8 V DC
Residual ripple
% 5
Supply current
mA Norm./max. 9/16 at signal 0
12/22 at signal 1
Siemens MPI, (optional)
yes (Notice: A short-circuit will result if 0 V or earth is applied to the outputs in the event that the supply voltage is connected to the wrong poles.)
Potential isolation
from power supply: yes
From the inputs: yes
to the interface: yes
to the memory card: yes
Rated operational current at signal „1” DC per channel
Ie A Max. 0.5
Residual current on 0 signal per channel
mA < 0.1
Max. output voltage
V 2.5 (signal 0 at external load < 10 MΩ)
U = Ue – 1 V (signal 1 at Ie = 0.5 A)
Short-circuit protection
Yes, thermal (analysis via diagnostics input I16, I15; R15, R16)
Short-circuit tripping current for Ra ≦ 10 mΩ
A 0.7 ≦ Ie ≦ 2 per output
Total short-circuit current
A 8
Peak short-circuit current
A 16
Thermal cutout
Yes
Max. operating frequency with constant resistive load
Operations/h 40000
Parallel connection of outputs
With resistive load, inductive load with external suppressor circuit, combination within a group
Group 1: Q1 to Q4
Number of outputs
max. 4
Max. total current
A 2 (Caution! Outputs must be actuated simultaneously and for the same length of time.)
Output status indication
LCD-display
Inductive load to EN 60947-5-1
Without external suppressor circuit
T0.95 = 1 ms, R = 48 Ω, L = 16 mH
Utilization factor
g 0.25
Duty factor
% DF 100
Max. switching frequency f = 0.5 Hz (max. DF = 50 %)
Operations 1500
DC-13, T0.95 = 72 ms, R = 48 Ω, L = 1.15 H
Utilization factor
g 0.25
Duty factor
% DF 100
Max. switching frequency f = 0.5 Hz (max. DF = 50 %)
Operations 1500
T0.95 = 15 ms, R = 48 Ω, L = 0.24 H
Utilization factor
g 0.25
Duty factor
% DF 100
Max. switching frequency f = 0.5 Hz (max. DF = 50 %)
Operations 1500
With external suppressor circuit
Utilization factor
g 1
Duty factor
% DF 100
Max. switching frequency, max. duty factor
Operations Depending on the suppressor circuit
Supply voltage UAux
Siemens MPI, (optional)
yes (Notice: A short-circuit will result if 0 V or earth is applied to the outputs in the event that the supply voltage is connected to the wrong poles.)
Power loss
P W 2

 

Approvals
Product Standards IEC/EN see Technical Data; UL 508; CSA C22.2 No. 142-M1987; CSA C22.2 No. 213-M1987; CE marking
UL File No. E135462
UL Category Control No. NRAQ
CSA File No. 012528
CSA Class No. 2252-01 + 2258-02
North America Certification UL listed, CSA certified
Degree of Protection IEC: IP20, UL/CSA Type: –