Control relay, 24 V DC, 12DI(4AI), 6DO relays, time, expandable, easyNet
Part no. EASY819-DC-RCX
Catalog No. 256270

Alimentación: 24 VCD

Entradas digitales: 12

Salidas tipo: Relevador 6

4 entradas Analógicas

Reloj tiempo real: Si

Expandible: 1 Mód.

 

 

1 disponibles

Descripción

 279 total views,  1 views today

Delivery program
Product range
Control relays easyRelay
Basic function
easy800 (expandable, easyNet)
Description
Expandable: Digital/analog inputs/outputs and AS-Interface, PROFIBUS-DP, CANopen®, DeviceNet bus systems
Bus system easyNet on board
customized laser inscription or delivery with user program possible with EASY-COMBINATION-* product (article No. 2010781)
Inputs
Digital input count
digital: 12
digital: 12; of which can be used as analog: 4
Digital
12
of which can be used as analog
4
Outputs
Type
Relay
Quantity of outputs
Relays: 6
Outputs
Number 6
Relay 10 A (UL)
6
Additional features
Display
without display, without keypad
Real time clock
Expansions
Expandable
Networkable (easyNet)
Supply voltage
24 V DC
Software
EASY-SOFT-PRO

Technical data
General
Standards
EN 55011, EN 55022, IEC/EN 61000-4, IEC 60068-2-6, IEC 60068-2-27
Dimensions (W x H x D)
mm 107.5 x 90 x 72 (6 PE)
Weight
kg 0.3
Mounting
Top-hat rail IEC/EN 60715, 35 mm or screw fixing using fixing brackets ZB4-101-GF1 (accessories)
Terminal capacities
Solid
mm2 0.2/4 (AWG 22 – 12)
Flexible with ferrule
mm2 0.2/2.5 (AWG 22 – 12)
Standard screwdriver
mm 3.5 x 0.8
Max. tightening torque
Nm 0.6
Climatic environmental conditions
Operating ambient temperature
°C In accordance with IEC 60068-2-1, -25 – +55
Condensation
Take appropriate measures to prevent condensation
Storage
ϑ °C In accordance with IEC 60068-2-1, -2, -14
-40 – +70
relative humidity
% in accordance with IEC 60068-2-30, IEC 60068-2-78
5 – 95
Air pressure (operation)
hPa 795 – 1080
Ambient conditions, mechanical
Protection type (IEC/EN 60529, EN50178, VBG 4)
IP20
Vibrations
3,5 mm / 1 g Hz In accordance with IEC 60068-2-6
constant amplitude 0.15 mm: 10 – 57
constant acceleration 2 g: 57 – 150
Mechanical shock resistance (IEC/EN 60068-2-27) semi-sinusoidal 15 g/11 ms
Impacts 18
Drop to IEC/EN 60068-2-31
Drop height mm 50
Free fall, packaged (IEC/EN 60068-2-32)
m 1
Mounting position
Vertical or horizontal
Electromagnetic compatibility (EMC)
Overvoltage category/pollution degree
III/2
Electrostatic discharge (ESD)
applied standard
according to IEC EN 61000-4-2
Air discharge
kV 8
Contact discharge
kV 6
Electromagnetic fields (RFI) to IEC EN 61000-4-3
V/m 0.8 – 1.0 GHz: 10
1.4 – 2 GHz: 3
2.0 – 2.7 GHz: 1
Radio interference suppression
EN 55011 Class B
Burst
kV according to IEC/EN 61000-4-4
power pulses (Surge)
according to IEC/EN 61000-4-5
1 kV (supply cables, symmetrical)
Immunity to line-conducted interference to (IEC/EN 61000-4-6)
V 10
Insulation resistance
Clearance in air and creepage distances
EN 50178, UL 508, CSA C22.2, No. 142
Insulation resistance
EN 50178
Back-up of real-time clock
Back-up of real-time clock
① Backup time (hours) with fully charged double layer capacitor
② Service life (years)
Accuracy of real-time clock to inputs
s/day typ. ± 2 (± 0.2 h⁄Year)
depending on ambient air temperature fluctuations of up to ± 5 s/day (± 0.5 h⁄year) are possible
Repetition accuracy of timing relays
Accuracy of timing relays (of values)
% ± 0.02
Resolution
Range “S”
ms 5
Range “M:S”
s 1
Range “H:M”
min 1
Retentive memory
Write cycles of the retentive memory
1012 (read⁄write cycles)
Power supply
Rated operational voltage
Ue V 24 DC (-15/+20%)
Permissible range
Ue 20.4 – 28.8 V DC
Residual ripple
% ≦ 5
Siemens MPI, (optional)
yes
Input current
140 mA at Ue
Voltage dips
ms ≤ In accordance with IEC 61131-2
≤ 20
Fuse
A ≧ 1A (T)
Power loss
P W Normally 3.4
Digital inputs 24 V DC
Number
12
Inputs can be used as analog inputs
4 (I7, I8, I11, I12)
Potential isolation
from power supply: no
between digital inputs: no
from the outputs: yes
to interface/memory card: no
to easyLink: no
to easyNet: yes
Rated operational voltage
Ue V DC 24
Input voltage
V DC Signal 0: ≦ 5 (I1 – I6, I9, I10, ≦ 8 (I7, I8, I11, I12)
Signal 1: ≧ 15 (I1 – I6, I9, I10), ≧ 8 (I7, I8, I11, I12)
Input current at signal 1
mA I1 – I6, I9, I10: 3.3 (at 24 V DC)
I7, I8, I11, I12: 2.2 (at 24 V DC)
Deceleration time
ms 20 (0 -> 1/1 -> 0, Debounce ON)
normally 0.025 (0 -> 1/1 -> 0, Debounce OFF, I1 – I4)
normally 0.25 (0 -> 1/1 -> 0, Debounce OFF, I5, I6, I9, I10)
normally 0.15 (0 -> 1/1 -> 0, Debounce OFF, I7, I8, I11, I12)
Cable length
m 100 (unshielded)
Frequency counter
Number
4 (I1, I2, I3, I4)
Counter frequency
kHz ≦ 5
Pulse shape
Square
Pulse pause ratio
1:1
Cable length
m ≦ 20 (screened)
Incremental counter
Number of counter inputs
2 (I1 + I2, I3 + I4)
Counter frequency
kHz ≦ 3
Pulse shape
Square
Signal offset
90°
Pulse pause ratio
1:1
Rapid counter inputs
Number
4 (I1, I2, I3, I4)
Cable length
m ≦ 20 (screened)
Counter frequency
kHz < 5
Pulse shape
Square
Pulse pause ratio
1:1
Analog inputs
Number
4 (I7, I8, I11, I12)
Potential isolation
from power supply: no
between digital inputs: no
from the outputs: yes
to interface/memory card: no
to easyLink: no
to easyNet: yes
Input type
DC voltage
Signal range
0-10 V DC
Resolution
0.01 V analog
0.01 V digital
10 Bit (value 0 – 1023)
Input impedance
11.2
Accuracy of actual value
Two EASY devices
% ± 3
Within a single device
% ± 2, (I7, I8, I11, I12) ± 0.12 V
Conversion time, analog/digital
ms each CPU cycle
Input current
mA < 1
Cable length
m ≦ 30, screened
Relay outputs
Number
6
Outputs in groups of
1
Parallel switching of outputs for increased output
Not permissible
Protection of an output relay
Miniature circuit-breaker B16 or fuse 8 A (slow)
Potential isolation
from power supply: yes
From the inputs: yes
between digital inputs: yes
to the interface: yes
to easyLink: yes
to easyNet: yes
Safe isolation according to EN 50178: 300 V AC
Basic isolation: 600 V AC
Lifespan, mechanical
Operations x 106 10
Contacts
Conventional thermal current (10 A UL)
A 8
Recommended for load: 12 V AC/DC
mA > 500
Short-circuit-proof cos ϕ = 1, characteristic B16 at 600 A
A 16
Short-circuit-proof cos ϕ = 0.5 to 0.7, characteristic B16 at 900 A
A 16
Rated impulse withstand voltage Uimp of contact coil
kV 6
Rated operational voltage
Ue V AC 250
Rated insulation voltage
Ui V AC 250
Safe isolation according to EN 50178
V AC 300 between coil and contact
300 between two contacts
Making capacity
AC–-15, 250 V AC, 3 A (600 ops./h)
Operations 300000
DC-13, L/R ≦ 150 ms, 24 V DC, 1 A (500 S/h)
Operations 200000
Breaking capacity
AC-15, 250 V AC, 3 A (600 Ops./h)
Operations 300000
DC-13, L/R ≦ 150 ms, 24 V DC, 1 A (500 S/h)
Operations 200000
Filament bulb load
1000 W at 230/240 V AC
Operations 25000
500 W at 115/120 V AC
Operations 25000
Fluorescent lamp load
Fluorescent lamp load 10 x 58 W at 230/240 V AC
With upstream electrical device
Operations 25000
Uncompensated
Operations 25000
Fluorescent lamp load 1 x 58 W at 230/240 V AC, conventional, compensated
Operations 25000
Switching frequency
Mechanical operations
x 106 10
Switching frequency
Hz 10
Resistive load/lamp load
Hz 2
Inductive load
Hz 0.5
UL/CSA
Uninterrupted current at 240 V AC
A 10
Uninterrupted current at 24 V DC
A 8
AC
Control Circuit Rating Codes (utilization category)
B 300 Light Pilot Duty
Max. rated operational voltage
V AC 300
max. thermal continuous current cos ϕ = 1 at B 300
A 5
max. make/break cos ϕ ≠ capacity 1 at B 300
VA 3600/360
DC
Control Circuit Rating Codes (utilization category)
R 300 Light Pilot Duty
Max. rated operational voltage
V DC 300
Max. thermal uninterrupted current at R 300
A 1
Max. make/break capacity at R 300
VA 28/28
Supply voltage UAux
Power loss
P W 3.4
Network easyNet
Data transfer rate/distance
1000 KBit/s, 6 m
500 KBit/s, 25 m
250 Kbit/s, 40 m
125 Kbit/s, 300 m
50 KBit/s, 300 m
20 KBit/s, 700 m
10 KBit/s, 1000 m
Lengths from 40 m can be obtained only with cables with reinforced cross-section and terminal adapter.
Potential isolation
from power supply POW: yes
From the inputs: yes
from the outputs: yes
to easyLink: yes
to the interface: yes
Bus termination (first and last station)
yes
Terminal types
RJ45, 8-polig
Terminal capacity
up to 1000 m, < 16 mΩ/m: 1.5 (AWG: 16)
up to 600 m, < 26 mΩ/m: 0.75 – 0.8 (AWG: 18)
up to 600 m, < 26 mΩ/m: 0.5 – 0.6 (AWG: 20, 19)
up to 400 m, < 40 mΩ/m: 0.34 – 0.5 (AWG: 22, 21, 20)
up to 250 m, < 60 mΩ/m: 0.25 – 0.34 (AWG: 23, 22)
up to 175 m, < 70 mΩ/m: 0.13 (AWG: 26)
up to 40 m, < 140 mΩ/m: 1.5 (AWG: 16)

 

Approvals
Product Standards IEC/EN see Technical Data; UL 508; CSA C22.2 No. 142-M1987; CSA C22.2 No. 213-M1987; CE marking
UL File No. E135462
UL Category Control No. NRAQ
CSA File No. 012528
CSA Class No. 2252-01 + 2258-02
North America Certification UL listed, CSA certified
Degree of Protection IEC: IP20, UL/CSA Type: –